PS265L-50G High Frequency Phase Stable Coaxial Cable

PS265L-50G High Frequency Low Loss Phase Stable Coaxial Cable Structure Diagram
PS265L-50G Cable Cross-Section Structure

PS265L-50G High Frequency Phase Stable Coaxial Cable

50 GHz Ultra-High Frequency Low Loss Phase-Stable Coaxial Cable

Max Frequency:50 GHz

Screening: >100 dB

Phase Stability ±0.3 °/GHz

Outer Diameter:2.65 mm

Structure & Construction Characteristics

Structure LayerItemMaterialConstruction (mm)Nom. O.D. (mm)
Inner ConductorConductor MaterialSilver Plated Copper1 / 0.560.56
InsulationDielectric MaterialLD-PTFE1.70
Inner ShieldFirst ShieldSilver Plated Copper Strip1.85
InterlayerSecond ShieldHigh Temperature Aluminium Foil1.98
Outer ShieldThird ShieldAlloy Wire Braid2.24
JacketOuter Protective LayerFEP2.65
Mechanical & Environmental ParameterStandard Value
Min. Bending Radius (Static)6.00 mm
Min. Bending Radius (Dynamic)15.00 mm
Weight0.016 kg/m
Operating Temperature Range-55 °C to +125 °C

Electrical & Mechanical Characteristics

Electrical ParameterStandard Value
Impedance50 Ohm
Capacitance87 pF/m
Velocity of Propagation76%
Max Operating Frequency50 GHz
Screening Effectiveness> 100 dB
Dielectric Withstanding Voltage500 V DC
Phase Change VS Bending±0.3 °/GHz
Phase Change VS Temperature (-45~+85℃)1500 PPM

Attenuation & Power Handling @ 25℃ & Sea Level

Calculation Formula: IL = K1 * sqrt(F_MHz) + K2 * F_MHz [dB/100m]
Constants: K1 = 1.942426242 | K2 = 0.001196918

Frequency (MHz)Nom. Attenuation (dB/100m @ 25℃)Max Power Handling (W @ 40℃)
50044.03314
100062.62221
3000109.98126
6000157.6488
10000206.2167
12000227.1561
16000264.8552
18000282.1549
26500347.9240
30000372.3537
40000436.3632

Cross Reference / Equivalent ReplacementThe PS265L-50G high-frequency coaxial cable serves as a direct drop-in replacement for HUBER+SUHNER Minibend-086L (32024), offering matching mechanical dimensions, electrical performance, and phase stability.

Frequently Asked Questions

What is the maximum operating frequency of PS265L-50G?

The PS265L-50G cable supports an operating frequency up to 50 GHz with stable 50 Ohm impedance and consistent phase performance.

What does the model number PS265L-50G signify?

PS stands for Phase Stable, 265 represents the nominal outer diameter of 2.65 mm, L indicates Low Loss construction (LD-PTFE dielectric), and 50G specifies the 50 GHz upper frequency limit.

Is PS265L-50G suitable for dynamic high-frequency test environments?

Yes. Featuring a dynamic minimum bend radius of 15.00 mm and a phase stability vs. bending specification of ±0.3 °/GHz, it is ideally suited for test assemblies and microwave interconnects

Need a Custom Solution?

To design the right custom RF coaxial cable, please share key details such as frequency range, application, required flexibility, installation space limitations, temperature requirements, and any existing cable model you are replacing. The more information you provide, the faster we can recommend the optimal cable solution.