PS400L-40G-F Phase Stable Coaxial Cable (Up to 40GHz) | Aqua FEP

PS400L-40G-F coaxial cable construction showing silver plated copper conductor, LD-PTFE insulation, double shield, and FEP jacket
Exploded view of PS400L-40G-F 40GHz Phase Stable Coaxial Cable

PS400L-40G-F Phase Stable Coaxial Cable ( 40GHz)

40GHz High-Frequency Phase-Stable Coaxial Cable (LD-PTFE Dielectric)

Max Frequency:DC-40GHz

Velocity of Prop.77%

Phase Stability ±0.2 °/GHz

Outer Diameter:4.0mm

Structure & Construction Characteristics

LayerItem / MaterialConstruction (mm)Nom. O.D. (mm)
Inner ConductorSilver Plated Copper (SPC)1 / 0.930.93
InsulationLow Density PTFE (LD-PTFE)2.75
Inner ShieldSilver Plated Copper Strip2.95
Outer ShieldSilver Plated Copper Braid3.35
JacketAqua FEP4.00

Mechanical & Environmental Parameters

Min. Bending Radius (Static)16.00 mmWeight0.036 kg/m
Min. Bending Radius (Dynamic)38.00 mmOperating Temperature Range-55 ℃ to +165 ℃

Electrical & Mechanical Characteristics

Impedance50 ΩVelocity of Propagation77%
Capacitance88 pF/mMax Operating Frequency40 GHz
Screening Effectiveness>90 dBDielectric Withstanding Voltage1000 V DC
Phase Change vs Bending±0.2 °/GHzPhase Change vs Temperature (-45~+85℃)≤1500 PPM

Attenuation & Power Handling @ 25℃ & Sea Level

Attenuation Calculation Formula:
IL = K1 * sqrt(F_MHz) + K2 * F_MHz  |  (K1 = 1.11183141, K2 = 0.000943596)

Frequency (MHz)Nom. Attenuation (dB/100m @ 25℃)Max Power Handling (W @ 40℃)
50025.33651
100036.10457
240056.73291
300063.73259
600091.78180
8000106.99154
10000120.62137
12400135.51122
18000166.1599
26500206.0080
40000260.1163

Industry Cross-Reference Interchangeability

The PS400L-40G-F offers direct functional and mechanical equivalence to standard industry micro-coaxial cable types including FA147A and 147-style phase stable cable assemblies.

Frequently Asked Questions

What dielectric material is utilized in the PS400L-40G-F cable to achieve phase stability?

The PS400L-40G-F incorporates Low Density PTFE (LD-PTFE), providing a velocity of propagation of 77% and phase stability of ±0.2 °/GHz during flexure.

What is the maximum insertion loss for this cable at 40 GHz?

Nominal attenuation at 40 GHz (40,000 MHz) is 260.11 dB/100m at sea level and 25℃ ambient temperature.

What type of shielding construction does PS400L-40G-F feature?

It uses a dual-shield structure featuring an inner silver-plated copper strip wrapped under an outer silver-plated copper wire braid, delivering >90 dB shielding effectiveness.

Need a Custom Solution?

To design the right custom RF coaxial cable, please share key details such as frequency range, application, required flexibility, installation space limitations, temperature requirements, and any existing cable model you are replacing. The more information you provide, the faster we can recommend the optimal cable solution.

Similar Posts