PS760L-18G-AF 18GHz Low Loss Phase Stable Coaxial Cable

PS760L-18G-AF high frequency coaxial cable exploded view showing silver plated copper center conductor, LD-PTFE dielectric, double shielding, and aqua FEP jacket
Exploded structural diagram of PS760L-18G-AF 18GHz phase stable coaxial cable

PS760L-18G-AF 18GHz Low Loss Phase Stable Coaxial Cable

18GHz Phase-Stable Low-Loss Coaxial Cable (LD-PTFE High Density Dielectric)

Max Frequency:DC-18GHz

Velocity of Prop.77%

Phase Stability ±0.3 °/GHz

Outer Diameter:7.6mm

Structure & Construction Characteristics

Structure ElementMaterialConstruction (mm)Nom. O.D. (mm)
Inner ConductorSilver Plated Copper1 / 2.062.06
InsulationLD-PTFE (Low-Density PTFE)6.05
Inner ShieldSilver Plated Copper Strip6.25
Outer ShieldSilver Plated Copper Wire Braid6.85
JacketAqua FEP7.60

Mechanical & Environmental Parameters

Mechanical & Environmental ParameterValue
Min Bending Radius (Static)38.00 mm
Min Bending Radius (Dynamic)76.00 mm
Weight0.135 kg/m
Operating Temperature-55 to +165 ℃

Electrical & Mechanical Characteristics

ParameterValue
Impedance50 Ω
Capacitance87 pF/m
Velocity of Propagation (VP)77%
Max Operating Frequency18 GHz
Screening Effectiveness> 90 dB
Dielectric Withstanding Voltage (DC)3000 V
Phase Change VS Bending±0.3 °/GHz
Phase Change VS Temperature (-45 to +85℃)≤ 1500 PPM

Attenuation & Power Handling @ 25℃ & Sea Level

Insertion Loss Calculation Formula:
IL = K1 * sqrt(F_MHz) + K2 * F_MHz (dB/100m)
Constants: K1 = 0.4736052, K2 = 0.001186495

Frequency (MHz)Attenuation (dB/100m)Power Handling (W @ 40℃)
50011.182756
100016.161907
300029.501045
400034.70888
600043.80704
800051.85594
1000059.23520
1200066.12466
1400072.65424
1600078.89391
1800084.90363

Cross Reference & Replacement
The PS760L-18G-AF is designed as a direct Form-Fit-Function drop-in alternative to Astrolabe 32051, providing matching attenuation profile, phase stability, and mechanical dimensions.

Frequently Asked Questions

What makes PS760L-18G-AF suitable for phase-critical applications up to 18 GHz?

 The combination of a Low-Density PTFE (LD-PTFE) dielectric and a dual silver-plated copper shield (strip + braid) ensures minimal phase shift over flexure (±0.3°/GHz) and temperature fluctuations (≤1500 PPM from -45°C to +85°C).

Can PS760L-18G-AF directly replace Astrolabe 32051 cable assemblies?

Yes. PS760L-18G-AF matches the electrical impedance (50 Ohm), velocity of propagation (77%), outer diameter (7.60 mm), and attenuation performance of Astrolabe 32051, making it a fully compatible cross-reference.

What are the environmental limits for the Aqua FEP jacket option?

The fluorinated ethylene propylene (FEP) jacket operates within -55°C to +165°C, offering excellent resistance to chemicals, moisture, and mechanical abrasion in demanding aerospace or test lab environments.

Need a Custom Solution?

To design the right custom RF coaxial cable, please share key details such as frequency range, application, required flexibility, installation space limitations, temperature requirements, and any existing cable model you are replacing. The more information you provide, the faster we can recommend the optimal cable solution.